Kenneth Benzie (Benie) 2c4588149f Add diodes to input CV conditioning
Add a shotkey diode to output of the CV conditioning stages to dump
negative voltage to ground. The maximum voltage range sent to the VC
pins of the AS3360 is 0-2.1V.

Add documentation to the schematic detailing how each chip is configured
and suggesting alternative resistor values for the first CV conditioning
stage for 0-5V and 0-8V operation.
2019-06-29 13:00:29 +01:00
2019-06-16 17:35:45 +01:00
2019-06-28 21:16:25 +01:00
Description
6hp tile providing two VCA circuits each with three jacks from left to right; IN, CV, OUT.
812 KiB